Nevion Flashlink Compact II Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Optyka Nevion Flashlink Compact II. Nevion Flashlink Compact II User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 29
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
Nevion
Nordre Kullerød 1
3241 Sandefjord
Norway
Tel: +47 33 48 99 99
nevion.com
Flashlink Compact II
FC-3G-EO-OE-36+2C
FC-3G-EO-36+1C
FC-3G-EO-OE-36+1C
FC-3G-OE-36+2C
FC-3G-EO-36+2C
FC-3G-OE-36
FC-3G-EO-36
FC-3G-EO-OE-36
FC-3G-OE-18
FC-3G-EO-18
FC-3G-OE-36+1C
User manual
Rev. A
Przeglądanie stron 0
1 2 3 4 5 6 ... 28 29

Podsumowanie treści

Strona 1 - User manual

Nevion Nordre Kullerød 1 3241 Sandefjord Norway Tel: +47 33 48 99 99 nevion.com Flashlink Compact II FC-3G-EO-OE-36+2C FC-3G-EO-36+1C FC-3G-EO-OE-36+

Strona 2 - Nevion Support

Flashlink Compact II Rev. A nevion.com | 10 2.1.4 FC-3G-OE-36 Power A indicator: Gives status on power supply connected to the Power A con

Strona 3 - Contents

Flashlink Compact II Rev. A nevion.com | 11 2.1.5 FC-3G-EO-OE-36 The receiver module is always the upper row and the transmitter module alwa

Strona 4 - 1 Product overview

Flashlink Compact II Rev. A nevion.com | 12 2.1.6 CWDM filter placement The CWDM filters included in some of the variant are mounted in the

Strona 5 - 2 Specifications

Flashlink Compact II Rev. A nevion.com | 13 2.2 Rear view 2.2.1 FC-3G-EO-18 Earth point: For connection to internal earth bar in 19” BNC:

Strona 6

Flashlink Compact II Rev. A nevion.com | 14 2.2.3 FC-3G-OE-18 Earth point: For connection to internal earth bar in 19” BNC: Electrical 3G

Strona 7 - 2.1 Front view

Flashlink Compact II Rev. A nevion.com | 15 2.2.5 FC-3G-EO-OE-36 The optical to electrical is always the upper row and the electrical to opt

Strona 8 - 2.1.2 FC-3G-EO-36

Flashlink Compact II Rev. A nevion.com | 16 3 Connections 1.1 Power connection Figure 3 shows the power connections of the unit as well as th

Strona 9 - 2.1.3 FC-3G-OE-18

Flashlink Compact II Rev. A nevion.com | 17 4 Replacing fan modules Flashlink Compact II will report an alarm in Multicon Gyda if any

Strona 10 - 2.1.4 FC-3G-OE-36

Flashlink Compact II Rev. A nevion.com | 18

Strona 11 - 2.1.5 FC-3G-EO-OE-36

Flashlink Compact II Rev. A nevion.com | 19 5 Configuration Flashlink Compact II can operate in two modes, Stand alone and Multicon Gyda cont

Strona 12

Flashlink Compact II Rev. A nevion.com | 2 Nevion Support Nevion Europe P.O. Box 1020 3204 Sandefjord, Norway Support phone 1: +47 33 48 99

Strona 13 - 2.2 Rear view

Flashlink Compact II Rev. A nevion.com | 20 The switches 4-7 set the slot address: SW4 SW5 SW6 SW7 Slot OFF OFF OFF OFF 1 ON OFF OFF OFF 2 OF

Strona 14 - 2.2.4 FC-3G-OE-36

Flashlink Compact II Rev. A nevion.com | 21 5.2.2 Multicon Gyda configuration The Flashlink Compact II does not store configuration set from

Strona 15 - 2.2.5 FC-3G-EO-OE-36

Flashlink Compact II Rev. A nevion.com | 22 5.2.2.7 Optical output Turns on or off the optical output. For safety reason turn off none used

Strona 16 - 3 Connections

Flashlink Compact II Rev. A nevion.com | 23 5.2.3 Multicon Gyda information On top of the Multicon Gyda information tab a dynamical picture

Strona 17 - 4 Replacing fan modules

Flashlink Compact II Rev. A nevion.com | 24 6 Upgrade firmware For upgrading the firmware the switch 8 has to be set to on; Multicon G

Strona 18 -

Flashlink Compact II Rev. A nevion.com | 25 7 Nevion SFP A list of valid Nevion SFP for the Flashlink Compact II with Nevion ordering number.

Strona 19 - 5 Configuration

Flashlink Compact II Rev. A nevion.com | 26 8 Laser safety precautions These are guidelines to limit hazards from laser exposure. All the ava

Strona 20

Flashlink Compact II Rev. A nevion.com | 27 General environmental requirements for Nevion equipment 1. The equipment will meet the guaranteed

Strona 21

Flashlink Compact II Rev. A nevion.com | 28 Product Warranty The warranty terms and conditions for the product(s) covered by this m

Strona 22

Flashlink Compact II Rev. A nevion.com | 29 Appendix A Materials declaration and recycling information A.1 Materials declaration For product

Strona 23

Flashlink Compact II Rev. A nevion.com | 3 Contents Revision history ...

Strona 24 - 6 Upgrade firmware

Flashlink Compact II Rev. A nevion.com | 4 1 Product overview The Flashlink compact II is a range of low power, low pri

Strona 25 - 7 Nevion SFP

Flashlink Compact II Rev. A nevion.com | 5 2 Specifications General Power +12V to 16V DC / 48W, max(standard SFP) 36channel variants 24

Strona 26 - 8 Laser safety precautions

Flashlink Compact II Rev. A nevion.com | 6 Electrical SDI input Connectors BNC, IEC 61169-8 Impedance 75ohm Cable equalization Automatic;

Strona 27

Flashlink Compact II Rev. A nevion.com | 7 2.1 Front view 2.1.1 FC-3G-EO-18 Power A indicator: Gives status on power supply connected to

Strona 28 - Product Warranty

Flashlink Compact II Rev. A nevion.com | 8 2.1.2 FC-3G-EO-36 Power A indicator: Gives status on power supply connected to the Power A conn

Strona 29 - A.2 Recycling information

Flashlink Compact II Rev. A nevion.com | 9 2.1.3 FC-3G-OE-18 Power A indicator: Gives status on power supply connected to the Power A conn

Komentarze do niniejszej Instrukcji

Brak uwag